Assume full accountability to fulfill all demands of our purchasers; attain continual advancements by marketing the advancement of our clientele; grow to be the final permanent cooperative partner of purchasers and maximize the interests of purchasers for
Bioreactor In Wastewater Treatment
, Mbr Membrane Bioreactor
, Membrane Process
, With a fast development and our customers come from Europe, United States, Africa and all over the world. Welcome to visit our factory and welcome your order, for further inquires please do not hesitate to contact us!
2022 Good Quality Membrane Filtering -
UF Membrane Module 10 inch PVC Ultrafiltration Membrane Module UFc250B River Water Treatment – Bangmo Detail:
Applications
Production of mineral water, mountain spring water and other sterile liquid.
Drinking treatment of tap water, surface water, well water, river water, etc.
Pretreatment of RO.
Treatment, recycle and reuse of industrial waste water.
Filtration Performance
This product is proven to have below filtering effects according to the service conditions of different water sources:
Ingredient |
Effect |
SS, Particles > 1μm |
Removal Rate ≥ 99% |
SDI |
≤ 3 |
Bacteria, Viruses |
> 4 log |
Turbidity |
< 0.1NTU |
TOC |
Removal Rate: 0-25% |
*Above data is obtained under the condition that feeding water turbidity is < 15NTU.
Product Parameters

Technical Parameters
Filtering Type |
Inside-out |
Membrane Material |
Modified PVC |
MWCO |
100K Dalton |
Membrane Area |
48m2 |
Membrane ID/OD |
1.0mm/1.8mm |
Dimensions |
Φ250mm*1710mm |
Connector Size |
DN50 Clamping |
Application Data
Pure Water Flux |
12,000L/H (0.15MPa, 25C) |
Designed Flux |
35-100L/m2.hr (0.15MPa, 25C) |
Suggested Working Pressure |
≤ 0.2MPa |
Maximum Transmembrane Pressure |
0.2MPa |
Maximum Working Temperature |
45°C |
PH Range |
Working: 4-10; Washing: 2-12 |
Operating Mode |
Cross-flow or Dead-end |
Feeding Water Requirements
Before feeding water, a security filter < 50 μm should be set to prevent blockage caused by large particles in raw water.
Turbidity |
≤ 15NTU |
Oil & Grease |
≤ 2mg/L |
SS |
≤ 20mg/L |
Total Iron |
≤ 1mg/L |
Continuous Residual Chlorine |
≤ 5ppm |
COD |
Suggested ≤ 500mg/L |
*Material of UF membrane is polymer organic plastic, there must not be any organic solvents in raw water.
Operating Parameters
Maximum Backwashing Pressure |
0.2MPa |
Backwashing Flow Rate |
100-150L/m2.hr |
Backwashing Frequency |
Every 30-60min. |
Backwashing Duration |
30-60s |
CEB Frequency |
0-4 times per day |
CEB Duration |
5-10min. |
CIP Frequency |
Every 1-3 months |
Washing Chemicals: |
Sterilization |
15ppm Sodium Hypochlorite |
Organic Pollution Washing |
0.2% Sodium Hypochlorite + 0.1% Sodium Hydroxide |
Inorganic Pollution Washing |
1-2% Citric Acid/0.2% Hydrochloric Acid |
Component Material
Component |
Material |
Membrane |
Modified PVC |
Sealing |
Epoxy Resins |
Housing |
UPVC |
Product detail pictures:
Related Product Guide:
We are also focusing on improving the stuff management and QC system so that we could keep great advantage in the fiercely-competitive business for
2022 Good Quality Membrane Filtering -
UF Membrane Module 10 inch PVC Ultrafiltration Membrane Module UFc250B River Water Treatment – Bangmo , The product will supply to all over the world, such as: Grenada
, Paraguay
, Lyon
, As an experienced factory we also accept customized order and make it same as your picture or sample specifying specification and customer design packing. The main goal of the company is to live a satisfactory memory to all the customers, and establish a long term win-win business relationship. For more information, please contact us. And It is our great pleasure if you like to have a personally meeting in our office.