Our well-equipped facilities and great good quality regulate throughout all stages of manufacturing enables us to guarantee total buyer gratification for
Ultrafiltration Water System
, Bioreactor Wastewater Treatment
, Membrane Filters For Water Treatment
, Many years of work experience, we have realized the importance of providing good quality products and whole heartedly before-sales and after-sales services.
2022 wholesale price Water Systems -
UF Membrane Module 10 inch PVC Ultrafiltration Membrane Module UFc250B River Water Treatment – Bangmo Detail:
Applications
Production of mineral water, mountain spring water and other sterile liquid.
Drinking treatment of tap water, surface water, well water, river water, etc.
Pretreatment of RO.
Treatment, recycle and reuse of industrial waste water.
Filtration Performance
This product is proven to have below filtering effects according to the service conditions of different water sources:
Ingredient |
Effect |
SS, Particles > 1μm |
Removal Rate ≥ 99% |
SDI |
≤ 3 |
Bacteria, Viruses |
> 4 log |
Turbidity |
< 0.1NTU |
TOC |
Removal Rate: 0-25% |
*Above data is obtained under the condition that feeding water turbidity is < 15NTU.
Product Parameters

Technical Parameters
Filtering Type |
Inside-out |
Membrane Material |
Modified PVC |
MWCO |
100K Dalton |
Membrane Area |
48m2 |
Membrane ID/OD |
1.0mm/1.8mm |
Dimensions |
Φ250mm*1710mm |
Connector Size |
DN50 Clamping |
Application Data
Pure Water Flux |
12,000L/H (0.15MPa, 25C) |
Designed Flux |
35-100L/m2.hr (0.15MPa, 25C) |
Suggested Working Pressure |
≤ 0.2MPa |
Maximum Transmembrane Pressure |
0.2MPa |
Maximum Working Temperature |
45°C |
PH Range |
Working: 4-10; Washing: 2-12 |
Operating Mode |
Cross-flow or Dead-end |
Feeding Water Requirements
Before feeding water, a security filter < 50 μm should be set to prevent blockage caused by large particles in raw water.
Turbidity |
≤ 15NTU |
Oil & Grease |
≤ 2mg/L |
SS |
≤ 20mg/L |
Total Iron |
≤ 1mg/L |
Continuous Residual Chlorine |
≤ 5ppm |
COD |
Suggested ≤ 500mg/L |
*Material of UF membrane is polymer organic plastic, there must not be any organic solvents in raw water.
Operating Parameters
Maximum Backwashing Pressure |
0.2MPa |
Backwashing Flow Rate |
100-150L/m2.hr |
Backwashing Frequency |
Every 30-60min. |
Backwashing Duration |
30-60s |
CEB Frequency |
0-4 times per day |
CEB Duration |
5-10min. |
CIP Frequency |
Every 1-3 months |
Washing Chemicals: |
Sterilization |
15ppm Sodium Hypochlorite |
Organic Pollution Washing |
0.2% Sodium Hypochlorite + 0.1% Sodium Hydroxide |
Inorganic Pollution Washing |
1-2% Citric Acid/0.2% Hydrochloric Acid |
Component Material
Component |
Material |
Membrane |
Modified PVC |
Sealing |
Epoxy Resins |
Housing |
UPVC |
Product detail pictures:
Related Product Guide:
Our advancement depends over the highly developed devices, excellent talents and continually strengthened technology forces for
2022 wholesale price Water Systems -
UF Membrane Module 10 inch PVC Ultrafiltration Membrane Module UFc250B River Water Treatment – Bangmo , The product will supply to all over the world, such as: Juventus
, Southampton
, Vancouver
, Our business activities and processes are engineered to make sure our customers have access to widest range of products with the shortest supply time lines. This achievement is made possible by our highly skilled and experienced team. We look for people who want to grow with us around the globe and stand out from the crowd. We have people who embrace tomorrow, have vision, love stretching their minds and going far beyond what they thought was achievable.