abide by the contract, conforms on the market requirement, joins from the market competition by its good quality likewise as provides more comprehensive and superb support for customers to let them become large winner. The pursue of the company, is definitely the clients' pleasure for
Ultrafiltration In Wastewater Treatment
, Cross Flow Membrane
, Microfiltration In Water Treatment
, Adhering to your small business principle of mutual positive aspects, we have now won superior popularity among our customers because of satisfactory solutions, excellent products and competitive selling prices. We warmly welcome clients from your home and overseas to cooperate with us for common achievement.
High reputation Membrane Water Filter -
MCR Membrane Module Reinforced PVDF BM-SLMCR-25 Surface Water Purification – Bangmo Detail:
Applications
● Purification of surface water.
● Reuse of heavy metal waste water.
● Pretreatment of RO.
Filtration Performance
Below filtration effects are proved according to the use of modified PVDF hollow fiber ultrafiltration membrane in different types of water:
No. |
Item |
Water Output Index |
1 |
TSS |
≤1mg/L |
2 |
Turbidity |
≤ 1 |
Specifications
Size

Chart 1 MBR Size
Technical Parameters
Filtering Direction |
Outside-in |
Membrane Material |
Reinforced Modified PVDF |
Precision |
0.03 micron |
Membrane Area |
25m2 |
Membrane ID/OD |
1.0mm/ 2.2mm |
Size |
785mm×2000mm×40mm |
Joint Size |
DN32 |
Component Material
Component |
Material |
Hollow Fiber Membrane |
Reinforced Modified PVDF |
Sealing Compound |
Epoxy Resins + Polyurethane (PU) |
Housing |
ABS |
Using Conditions
Proper pretreatments must be set when raw water contains a lot of impurities/coarse particles or large proportion of grease. Defoamer must be used to remove foams in membrane tank when necessary, please use alcoholic defoamer which is not easy to scale.
Item |
Limit |
Remark |
PH Range |
5-9 (2- 12 when washing) |
Neutral PH is better for bacterial culture |
Particle Diameter |
<2mm |
Prevent sharp particles to scratch membrane |
Oil & Grease |
≤2mg/L |
Prevent membrane fouling/sharp flux decrease |
Hardness |
≤150mg/L |
Prevent membrane scaling |
Application Parameters
Designed Flux |
15~40L/m2.h |
Backwashing Flux |
Twice the designed flux |
Operating Temperature |
5~45°C |
Maximum Operating Pressure |
-50KPa |
Suggested Operating Pressure |
≤-35KPa |
Maximum backwashing Pressure |
100KPa |
Operating Mode |
Continuous opeartion, intermittent backwashing air flushing |
Blowing Mode |
Continuous Aeration |
Aeration Rate |
4m3/h.piece |
Washing Period |
Clean water backwashing every 1~2h; CEB every 1~2 days;Offline washing every 6~12 months
(Above information is for reference only, please adjust
according to actual differential pressure change rule) |
Product detail pictures:
Related Product Guide:
Our business puts emphasis on the administration, the introduction of talented personnel, as well as the construction of team building, trying hard to further improve the standard and liability consciousness of staff members customers. Our enterprise successfully attained IS9001 Certification and European CE Certification of
High reputation Membrane Water Filter -
MCR Membrane Module Reinforced PVDF BM-SLMCR-25 Surface Water Purification – Bangmo , The product will supply to all over the world, such as: Jeddah
, Manchester
, Mecca
, Hard work to keep making progress, innovation in the industry, make every effort to high quality enterprise. We try our to build the scientific management model, to learn abundant professional knowledge, to develop advanced production equipment and production process , to create the first-call quality products, reasonable price , high quality of service , quick delivery , to give you create new value .